Jobs and Careers
AM

P&C Field Technologist Assoc-Sr.

American Electric Power
Zanesville, United Statesfull_timeVerifiedPosted 16 May 2025
💰 $88,920/yr

About the role

Job Posting End Date

05-27-2025

Please note the job posting will close on the day before the posting end date

Job Summary

Perform work associated with the installation, operation, testing and maintenance of fundamental protection and control devices and related equipment under general supervision. Such devices and equipment includes but is not limited to digital relays, electromechanical relays, intelligent electronic devices, Station Disturbance Recorders (SDR), digital fault recorders (DFR), event recorders, RTU's and station SCADA systems, statistical load metering, telemetering and transducers. Additionally, install, maintain and operate all power line carriers (PLC), tone, pilot wire, fiber and associated P&C communications equipment. Respond to emergency call-outs and coordinate prompt restoration of service to customers as required. This list is not intended to limit assignment of work or the degree of supervision under all operating conditions. Employee may perform miscellaneous, related, and incidental work in addition to that specifically outlined below.

Job Description

The power of AEP comes from our valued team of unique employees….the best in the business!  We’re proud to be one of the largest electric energy companies in the U.S., powering over 5 million homes and businesses, spanning across 11 states.  We’re passionate about making an innovative difference in the communities we serve.  We’re powering the future – today!

Are you a skilled and motivated P&C Field Technologist seeking a new opportunity in the Zanesville, OH vicinity?  Join our team where you’ll make an impact while contributing to the development and implementation of the systems and infrastructure needed to efficiently deliver energy services to our valued customers.


Job Description:
Perform work associated with the installation, operation, testing and maintenance of fundamental protection and control devices and related equipment under general supervision. Such devices and equipment includes but is not limited to digital relays, electromechanical relays, intelligent electronic devices, Station Disturbance Recorders (SDR), digital fault recorders (DFR), event recorders, RTU's and station SCADA systems, statistical load metering, telemetering and transducers. Additionally, install, maintain and operate all power line carriers (PLC), tone, pilot wire, fiber and associated P&C communications equipment. Respond to emergency call-outs and coordinate prompt restoration of service to customers as required. This list is not intended to limit assignment of work or the degree of supervision under all operating conditions. Employee may perform miscellaneous, related, and incidental work in addition to that specifically outlined below.

What You’ll Do:
 

1. Test fundamental protection & control devices and equipment periodically and as required.


 

2. Calibrate fundamental protection & control devices and equipment on a pre-established schedule and as required.


 

3. Assist with switching at all voltage levels under the direction of the proper Dispatching Authority.


 

4. Maintain test equipment in good working order.


 

5. Maintain accurate records, reports and drawings as required.


 

6. Operate a computer device to test, calibrate, and retrieve data from protection & control devices.


 

7. Assist in the installation, maintenance, and operation of all relays, power line carrier sets, station SCADA, and associated communications equipment or cables as assigned.


 

8. Troubleshoot and repair fundamental electromechanical relays.


 

9. Troubleshoot and repair microprocessor based relays at the card level, such as replacing power supplies, communications cards, I/O cards, etc.


 

10. Assist with the diagnosis of equipment failures, protection mis-operations, and assist with corrective action to perform repairs and prevent recurrence.


 

11. Ensure the circuitry, installation and operation of equipment is correct prior to placing equipment in service. Read electrical schematics and determine that the physical installation at the site is electrically equivalent to the schematic. Record test readings and results and determine they are within acceptable specifications and thus the physical installation will perform as per the design.


 

12. Basic fault analysis: obtain oscillography data to determine if the protective devices operated as per their issued relay settings.


 

13. Assisting a team in the installation, testing, and commissioning of new P&C systems for capital construction projects. Assist the on-site technical lead with directing the activities o

Apply for this role

Generate a tailored application kit with a matched cover letter, interview prep, and CV highlights — in under 60 seconds.

Apply Now →Generate Application Kit

Free account required — sign up in 30s

Company

American Electric Power

View company profile →