Facilities Maintenance Electrician (5:45am - 2:15pm) - Pay ($34.45 - $38.70) + $5,000 Sign-On Bonus
The Campbell's CompanyAbout the role
Since 1869, we've connected people through food they love. We’re proud to be stewards of amazing brands that people trust. Our portfolio includes the iconic Campbell’s brand, as well as Cape Cod, Chunky, Goldfish, Kettle Brand, Lance, Late July, Pacific Foods, Pepperidge Farm, Prego, Pace, Rao’s Homemade, Snack Factory, Snyder’s of Hanover. Swanson, and V8.
Here, you will make a difference every day. You will be supported to build a rewarding career with opportunities to grow, innovate and inspire. Make history with us.
Job Summary:
The Facilities Maintenance Electrician maintains existing electrical system infrastructure to ensure a safe and reliable electrical environment is provided for all employees, contractors, etc. The Maintenance Electrician also maintains facilities and production equipment to operate in the safest and most productive condition, supporting continuous improvement, production strategies, and plant reliability strategies.
Essential Job Duties:
- Understands and adheres to governmental regulatory programs and policies, including National Fire Protection Association (NFPA) 70 National Electric Code, NFPA 70B Electrical Maintenance, NFPA 70E Arc Flash Electrical Safety, NFPA 79 Electrical Standard for Industrial Machinery.
- Understands and adheres to Campbell’s Company Inc. company programs and policies.
- Practices and complies with all Campbells Company Inc. safety programs and procedures including Lock Out Tag Out (LOTO), Personal Protective Equipment (PPE), Confined Space Entry, Fire Suppression Impairment Process, Hot Work Permits, Arc Flash, 5S, etc.
- Application of Good Manufacturing Practices & Sanitary Design Principles.
- Attend classes, seminars, and in-house training as needed to maintain skill level with changes in the industry.
- Provide input to improve current maintenance, reliability, and production programs and strategies.
- Provide and receive support and cross training from other maintenance positions.
- Execute and document planned work during shift utilizing Computerized Maintenance Management System (CMMS).
- Execution and resolution of equipment break downs and repairs utilizing a variety of methodologies including but not limited to: Root Cause Analysis (RCA), Who, What, Where, When, Why, How, and How much did it cost (5W2H), Break Down Failure Analysis (BDFA), Cause Mapping, etc.
- Utilizes and supports predictive maintenance (PDM) technologies including Thermal Imaging, HIPOT Testing and Electrical Current Analysis to identify potential failures and perform follow-up actions to improve electrical infrastructure and equipment reliability and safety.
- Applies knowledge of technical documentation such as electrical drawings, mechanical drawings, Pipe and Instrumentation Diagrams (P& ID’s), technical manuals to improve equipment reliability and safety.
- Applies industry knowledge to troubleshoot hardware such as Programmable Logic Controller (PLC’s), Variable Frequency Drive (VFD’s), Building Automation System, Fire Alarm Control Panels etc.
- Participation in various required plant inspections: Occupational Safety and Health Administration (OSHA), NFPA, Sustainability, Fire, Switchgear & Breaker Testing, Electrical Upgrade Surveys, New Equipment Installation Evaluations, Daily Zone Inspections.
- Work closely with cross functional teams to develop and improve current capital processes by recommending needed facility and equipment improvement and needed replacement.
- Works variable hours across all shifts to assist in business related projects.
- Ability to participate in on-call rotation with other members of the facilities team.
- Ability to work during site outages including weekends (Occasionally), holidays, & off shifts (Occasionally)
- May assist in purchasing and inventory control of all spare parts. Makes recommendations for electrical spare parts.
- Repairs, Replaces, or upgrades facility related equipment as needed.
- Performs Electro-mechanical Preventative Maintenance (PM’s) as required.
- Verifies results of PDM Infrared scans and evaluates electrical issues to develop a plan of action for needed repairs.
- Performs other job-related projects, duties and assignments as required.
- Must have knowledge of NEC installations, sizing electrical feeders, raceway installations, branch circuits and equipment overcurrent/short circuit protection in addition to adhering to NEC box fill calculations and NEC article 250 Grounding requirements.
- Ability to bend and install rigid conduit runs and pull wire terminating into diverse types of panel boxes following arc flash and NFPA70E Safety Requirements.
Scope of Responsibility<
Apply for this role
Generate a tailored application kit with a matched cover letter, interview prep, and CV highlights — in under 60 seconds.
Apply Now →Generate Application KitFree account required — sign up in 30s